Nmsa gas detector pdf

It is designed for use as an integral part of an msa fixed gas detection system for. Assess potential worker exposure to combustible and toxic gases and vapors determine the appropriate gas and vapor monitoring needed for a workplace. The product may not perform as designed if it is not used and maintained in accordance with the. Printing 2009 nmsa 1978 new mexico medical society. Designed to provide thorough, continuous monitoring of many hazardous gases, the indooroutdoor ultima x series gas monitors offer excellent performance and msa quality craftsmanship. Altair 5x gas detector natural gas and pid msa safety. It is designed to be used when performing a hazard assessment to. This code covers the installation and removal of electrical conductors, equipment, and raceways. Chapter 58, article 21 nmsa 1978 may be cited as the mortgage loan company act. Information on class i division 1 and zone 1 wiring methods can be found in the nec and cec. Noaa flare detection data for number of identified flares in six states over a 5 year time. The altair 5x and altair 5x ir multigas detectors are designed to.

Assess potential worker exposure to combustible and toxic gases and vapors as well as low level of oxygen. Admissibility of polygraph or similar lie detector test results, or willingness to. Msa s gas and flame mapping service combines 150 years of gas detection experience with 3d technology to help you maximize the effectiveness of every sensor. The orion multigas detector is a lowcost, four gas portable detector featuring onebutton calibration, rugged construction with excellent resistance to dust and water penetration, and a 16 to 20hour run time. Kindly consult the invitation andor specification documents. Product software downloads msa safety united kingdom.

The ultralong battery life keeps the focus on safety and less on maintenance. Msa link pro gx2 fleet management software link pro version 1. Msa is dedicated to helping men and women work safely throughout the world. The altair 4xr can also provide realtime incident awareness to team members, supervisors, safety managers and others when paired with the msa altair connect app via a bluetooth. Our dedication to advanced technology and product durability not only helps to provide high level safety, but delivers a reduced total cost of ownership. Ultima x series gas detector msa safety united states. Striving for zero incidents before a shovel hits the ground. Detect gases and vapours in air only the altair 5x ir gas detector can also contain one infrared sensor to detect co2 or specific combustible gases up to 100 % vol. Adjustable wrench for conduit or cable gland connections not included. Msa s network of distributors can help find the right product for you. Gas calibration histories combustible and h2s gas simple, reliable and costeffective field wiring topology addressable detection loop for buildings the msa model 10k fire and gas system is ideal for use in compressor stations, drilling and production platforms, refineries. Instantly detect pressurized gas leaks with this highprecision, omnidirection acoustic detector utilizing gassonic ultrasonic technology. Check minimum concentration of a combustible gas the minimum concentration of a combustible gas in air that can ignite is defined as the lower explosive limit lel.

Smart sensor sensor that contains a microprocessor, allowing it to record data, communicate with other devices or control devices such as relays. This rule applies to all owners and operators of gas and hazardous. The instrument will perform as designed only if it is used and maintained in. Page 1 page 2 page 3 table of contents page 4 page 5 safety regulations page 6 liability information page 7 page 8 page 9 warranty page 10 description page 11 device hardware interfaces page 12 onscreen indicators page battery care page 14 page 15 viewing additional. The altair 4x is an extremely durable multigas detector that simultaneously measures up to four gases from a wide range of xcellr sensor options including combustible gases, o. Mortgage loan company act 2009 state of new mexico.

The ultima x5000 gas monitor is the future of gas detection for oxygen, toxic and combustible gases. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. The flameproof transmitter is housed in a powdercoated aluminum enclosure that will protect it in extremely dangerous conditions. A combus tible gas reading of xxx indicates the atmosphere is above 100%lel or 5.

Msa altair 4xr multigas detector lel, o2, co, h2s 10178557 lowest price online guaranteed. Msa altair 4x gas detector msa safety united states. The instrument will perform as designed only if it is used and maintained in accordance with the manufacturers instruction. Summary of contents for msa primax p page 1 secure the primax detector to the backplate as m6 14 screws, ensuring the sensor will be shown and tighten the two hexagon socket head pointing down. The ultima x5000 gas monitor, hereafter also called device, is a gas monitor for measuring toxic and combustible gases as well as oxygen. Altair 4xr gas multi gas detector msa safety canada. View and download msa altair 5x operating manual online. The nmisa currently has opportunities to tender for the supply of equipment. From rig to refinery, count on msa to keep you safe. Gd10p page 2 of 28 850811250r04 note this manual must be carefully read by those who have or will have the responsibility for the operation or maintenance of this product. At msa, we work tirelessly to build smarter, better gas detection instruments and sensors because workers around the world, who face potentially dangerous situations, deserve the best protection available. Designed to provide thorough, continuous monitoring of many hazardous gases, the indooroutdoor ultima x series gas monitors offer excellent performance and msa. Msa altair 4x gas detector 4 gas monitor that simultaneously measures up to 4 gases. Page 1 operating manual altair 4 four gas multigas detector manufactured by msa corporate center cranberry woods drive, cranberry township, pennsylvania 16066 pn 10088975 rev 1 yhls page 2 warning read this manual carefully before using the instrument.

Using sensors, the device tests the ambient air and triggers the alarm as soon as the gas exceeds a specific concentration level. Msa xcell gas sensors with trucal technology offer calibration cycles up to 18 months local calibration respected. Msa australia pty ltd 11 columbia way norwest business park baulkham hills nsw 2153. Ultima x series gas detector for indoor or outdoor continuous monitoring of hazardous gases. The gas transmitters advanced, multilingual oled display is easy to read and the unique touchscreen interface makes it simple to navigate.

Newsletter receive news and updates about our company, product range, safety solutions and services. Msa is a global organization committed to developing, manufacturing, and supplying safety products that help protect people and facility infrastructures. Pipeline general provision new mexico public regulation. Our employees make the difference thanks to their passion for protecting people in. In environments where contamination is possible, ensure that the flow remains unobstructed at the sensor. Failure to follow this may prevent gas detection and generate inaccurate readings. Gas detectors depend on an unimpeded gas flow for proper operation. The gas transmitters advanced, multilingual oled display is easy to read and the unique touchscreen interface makes it. The altair 5x gas detector is capable of measuring up to 6 gases simultaneously and is now available with integrated pid sensor for voc detection. Altair 4xr gas multi gas detector msa safety africa. Correct use the msa gas detector series 47k is designed to continuously monitor the atmosphere for the presence of potentially explosive gas or vapour in air in the range 0 to 100%lel. Like any piece of complex equipment, this instrument will perform as designed.

Operating manual altair 5x multi gas detector altair 5x. S4000ch combustible gas detector instruction manual. Weve been at the forefront of safety innovation since developing our edison electric cap lamp in 1914. The altair io360 gas detector offers four gas detection for high risk areas, including confined spaces, perimeter and general area monitoring. Designed to detect gases indoors or outdoors, our primax p gas transmitter measures oxygen and toxic and combustible gases. Each tender that has tender specific documentation and the general documents must also be completed. The new mexico oil and gas act new mexico energy, minerals.